Vios log integration
Log Integration Guide
Log Integration procedure:
To forward logs, make the following configuration.
Login to the Terminal as padmin user on VIOS
Initiate the OEM set up and installation environment.
Type the following command:
oem_setup_env
Enable Syslog daemon & updating Syslog Config file.
Activate syslog daemon to write into /var/log/syslog.out files.
In /etc/syslog.conf uncomment the following entry or add if it is not present:
*.debug /var/log/syslog.out rotate size 100k files 4
Also add the following lines to the syslog configuration file located in /etc/syslog.conf at the end of the file.
*.info @10.20.100.161
*.alert @10.20.100.161
*.notice @10.20.100.161
*.debug @10.20.100.161
*.err @10.20.100.161
*.crit @10.20.100.161
*.emerg @10.20.100.161
Replace 10.20.100.161 with Log Collector IP of specific branch.
Save the changes.
Create the log file in case it does not exist:
touch /var/log/syslog.out
Restart the syslog daemon.
refresh -s syslogd